Home > Products >Explosion-proof Electrical> QJZ (2) Intrinsic-Safety Vacuum Starter
QJZ (2) Intrinsic-Safety Vacuum Starter
QJZ (2) Series Mining Explosion Proof and Intrinsic-Safety Vacuum Electromagnetic Starter with Several Circuits
  • Image 01
  • 1

Application

This series of starter is applicable in coal mine downhole and the places filled with methane, coal dust and explosive mixture, in the no grounding three phases power grid rated voltage 660V or 1140V, rated total current of 2000A, acted as starting switch of the equipments in mining zone and other working interface; it can automatically shut off power and indicate fault signal when the circuit is meeting the faults of overload, short-circuit, over-voltage, under-voltage etc, also have leakage circuit and protection functions such as under-voltage, overload, loss of phase, short-circuit and leakage closedown etc can operate with single set control, single set duplicate speed control, twin sets duplicate speed control to control motor, and change motor phase order through separated switch when ceasing. Control starting, stopping of motors such as mining machine, scraper blade conveyor, main motor of rubber belt conveyor, oil pump, cooling fan and rubber belt extension motor, rewind motor, crusher, transfer conveyor, and protect motor and supplying power circuit, to reach the aim, supplying power equipments are automatically controlled in mining zone and other interface.

 

Features 

Protection and control system adopt advanced PLC, high precision data processing and advanced protection arithmetics, high protection precision, quick feedback speed. Have leakage closedown, overload, short-circuit, loss of phase, undervoltage and overvoltage protection function, also have advantages such as high intelligentize grade, stable performance, various control ways, reliable action etc.

Adopt demonstrating displayer, can indicate working state, parameters and fault type of switch, also have friendly customer interface, favorable man-machine dialog function, to greatly improve efficiency of judging fault and removing fault.

Indicating system: voltage, switch on-off state, three phases current of each loop on switch in real time.

All analog signals can be treated to digital signal, have strong anti-jamming capability, simple cable connection, bulk information quantum, reliable control etc.characteristics.

Can close and remote control and duplicate speed control.

Have completed self-check, self-diagnoses function, can easy to check protection and control system normal or not, and communication function with epigyny.

It has 127V of supplementary lighting and control power source.

Have RS485 or CAN communication port of intrinsic safety.

 

Main technical parameters

Type spec.

Rated voltage (V)

General current (A)

Isolation switch Qty

Single circuit current

Cable O.D.

Outline dimension

W×D×H(mm)

Auxilary circuit

Main circuit

Control circuit

QJZ-1660/1140(660)-4

1140

(660)

1660

4

400

42~78

9~23

3475×1292×1316

Non

QJZ-1660/1140(660)-6

QJZ-1660/1140(660)-8

QJZ-2000/1140(660)-9

2000

5

3556×1200×1184

127V,

1.5kVA

QJZ-2000/1140(660)-10

QJZ-2000/1140(660)-11

QJZ-2000/1140(660)-12